Sparger Assembly

MODEL W7950 SPARGER ASSEMBLY

is used to prepare a sample for taking a Degassed Cation Conductivity measurement.

Features:

  • Uses Inert Gas: no reboiler; does not alter sample temperature
  • High Purity: 316SS or plastic wetted parts
  • Discrete Measurements: analyze for either cation conductivity or degassed cation conductivity
  • Versatile: may optional enhancements available
     

 Sparger Assembly Data Sheet W7950

 

The DEGASSING SPARGER with NITROGEN GENERATOR

provides continuous, highly efficient removal of interfering soluble gases such as CO2 from a cation conductivity measurement without altering the sample temperature. There is no boiling of the sample, so no re-cooling or special sensors are required and there is no potential burn hazard to personnel. 

 Degassing Sparger with Nitrogen Generator Data Sheet

Copyright © 2015 Waters Equipment. All rights reserved.